Emissions and Permitting / Free calculator
Engine emissions: grams and ppm
Convert engine emissions between grams per brake horsepower-hour and dry ppm, with the heat rate and oxygen basis visible.
Type into any number field to pin it. Calculated fields carry a rust-colored rule. Clear a pin to let it solve again. Starting values are editable assumptions, not measured facts.
Your numbers
Verify all units and results for your own use.
Your results
Your worksheet
Download or copy the complete entered and calculated values without giving us an email address.
Read or copy the worksheet
Email is optional.
Full results and the worksheet are free above. Each button requests only the extra it names. No other list is bundled in.
Notification signup sends your email address and the notification you choose to Buttondown. Check your inbox to confirm. Worksheet and saved-link email delivery remain disabled.
Technical notes and factor sources
Factors as of: EPA Method 19: 2023-03-29; EPA ERT data dictionary: 2025-02-20; primary molecular-weight references reviewed 2026-10-31
Review date: 2026-10-31 (build review, not engineering signoff)
Calculation aid only. Results depend on the entered dry exhaust-flow basis, or on HHV heat rate and dry O2 when using the Method 19 route. A compliance concentration comes from a stack test, not this page. NOx is reported as NO2; VOC as propane is a stated equivalent, not total VOC mass for every mixture. Dry standard conditions: 20 C and 760 mm Hg. The reduced concentration relation cancels horsepower, so concentration can solve without horsepower; exhaust flow and mass rate still need power or heat input.
Declared relations
- 1 x gap + 1 x o2 = 20.9
- 1 x referenceGap + 1 x reference = 20.9
- heatInput = 1e-06 x hp x heatRate
- brakeBridge = 1 x grams x gap
- brakeBridge = 1 x ppm x mw x heatRate x selected source coefficient (see notes)
- oxygenBridge = 1 x ppm x referenceGap
- oxygenBridge = 1 x corrected x gap
- heatInput = 1 x dryFlow x gap x selected source coefficient (see notes)
- massRate = 2.5953802232026993e-09 x ppm x mw x dryFlow
- massRate = 0.002204622621848776 x grams x hp
- 1 x mw = 0
- dryFlow = 1 x flowPerHP x hp
- grams = 1.1772446664936414e-06 x ppm x mw x flowPerHP
All fields solve from the declared relations in either direction when a unique value exists. Calculated values use full precision. Conflicts use a relative tolerance of 0.01%, with an absolute floor of 0.000001. Zero divided by zero has no unique solution. A cleared field can be calculated again when other entries determine it.
Dry flow = heat input x Fd x 20.9 / (20.9 - measured O2).
lb/dscf = ppm x molecular weight / (385.3 x 1000000).
g/brake hp-hour = ppm x MW x heat rate x Fd x 20.9 x 453.59237 / (385.3 x 1000000000000 x (20.9 - measured O2)).
Corrected ppm = measured ppm x (20.9 - reference O2) / (20.9 - measured O2).
EPA Method 19 average Fd values are on a higher-heating-value basis. Mixed fuels and site-specific F-factors are not modeled. No default heat rate.
Default field basis: owner-stated rich-burn practice, 81.5 dscf/brake hp-hour with measured and reference O2 both 0.0 percent. These are editable starting values, not EPA defaults.
Direct dry flow = flow per brake hp-hour x horsepower. Direct g/brake hp-hour = ppm x molecular weight x flow per brake hp-hour x 453.59237 / (385.3 x 1000000).
The direct and Method 19 relations stay active together. If enough entered values make both routes computable and inconsistent, the solver flags a conflict rather than overriding either pin. Clear the flow-per-hp-hour pin to work the Method 19 route alone; that field may then be calculated from the remaining entries.
The owner points are approximate field conversions, not an exactly linear table. The tool retains 81.5 and full calculated precision rather than tuning a factor to force a match.
constants / sourced values
- Reference constant
- 385.3 dscf/lb-mol at 20 C and 760 mm Hg. Source: EPA ERT conversion, consistent with EPA Method 19 standard conditions. Factors as of 2025-02-20; review 2026-10-31.
- Reference constant
- 20.9 percent oxygen. Source: EPA Method 19 dry oxygen correction. Factors as of 2023-03-29; review 2026-10-31.
- Reference constant
- 453.59237 g/lb. Source: NIST SP 811 international pound. Factors as of 2026-10-31; review 2026-10-31.
- owner-dry-flow
- 81.5 dscf/brake hp-hour. Source: Owner field practice, stated 2026-10-31. Not an EPA value.. Factors as of 2026-10-31; review 2026-10-31.
- owner-exhaust-oxygen
- 0 percent dry O2. Source: Owner field practice, stated 2026-10-31. Not an EPA value.. Factors as of 2026-10-31; review 2026-10-31.
- owner-reference-oxygen
- 0 percent dry reference O2. Source: Owner field practice, stated 2026-10-31. Not an EPA value.. Factors as of 2026-10-31; review 2026-10-31.
fuels / sourced values
- Natural gas
- 8710 dscf/MMBtu HHV. Source: EPA Method 19 Table 19-2. Factors as of 2023-03-29; review 2026-10-31.
- Oil: crude, residual or distillate
- 9190 dscf/MMBtu HHV. Source: EPA Method 19 Table 19-2. Factors as of 2023-03-29; review 2026-10-31.
- Propane
- 8710 dscf/MMBtu HHV. Source: EPA Method 19 Table 19-2. Factors as of 2023-03-29; review 2026-10-31.
- Butane
- 8710 dscf/MMBtu HHV. Source: EPA Method 19 Table 19-2. Factors as of 2023-03-29; review 2026-10-31.
pollutantOptions / sourced values
- NOx as NO2
- 46.01 g/mol; numerically lb/lb-mol. Source: EPA Substance Registry: Nitrogen dioxide. Factors as of 2026-10-31; review 2026-10-31.
- CO
- 28.01 g/mol; numerically lb/lb-mol. Source: OSHA Method ID-209, Carbon Monoxide. Factors as of 2026-10-31; review 2026-10-31.
- SO2
- 64.07 g/mol; numerically lb/lb-mol. Source: FAO/JECFA Sulfur Dioxide monograph, 1998. Factors as of 2026-10-31; review 2026-10-31.
- Formaldehyde
- 30.03 g/mol; numerically lb/lb-mol. Source: OSHA 1910.1048 Appendix A: Formalin technical guidelines. Factors as of 2026-10-31; review 2026-10-31.
- VOC as propane
- 44.1 g/mol; numerically lb/lb-mol. Source: OSHA chemical data: Propane, molecular weight 44.1. Factors as of 2026-10-31; review 2026-10-31.
Sources by name
- EPA Method 19, 40 CFR Part 60 Appendix A-7, Table 19-2 and equations
- EPA ERT v7 data dictionary: ppm / lb per dscf conversion and oxygen correction
- NIST SP 811: pound to gram conversion
- EPA Substance Registry: Nitrogen dioxide
- OSHA Method ID-209, Carbon Monoxide
- FAO/JECFA Sulfur Dioxide monograph, 1998
- OSHA 1910.1048 Appendix A: Formalin technical guidelines
- OSHA chemical data: Propane, molecular weight 44.1
- Owner field practice, stated 2026-10-31. Owner-stated basis, not an EPA value.
Results are estimates for planning. Permit and engineering decisions need a qualified professional.
Keep the tools on your phone.
iPhone: open this page in Safari, tap Share, then Add to Home Screen. Android: use Chrome's Install app or Add to Home screen menu.
Preparing offline tools. Keep this page open until they are ready.
Your numbers stay in this browser on this device. Browser cleanup can remove them. We do not use cookies or send your numbers to a server.